RFTemp101 Logger Specifications:
Transmission Distance: 300 feet.
Transmitters Per Receiver: 8
Internal Channel
Temperature Accuracy: 0.5 deg C.
Temperature Resolution: 0.5 deg C.
Temperature Range: -40 Deg C to + 75 Deg C.
Remote Channel
| Thermocouple Type | Range | Resolution | Accuracy |
| J | -200 to + 1190 deg. C | 0.1 deg. C | 1 deg. C |
| K | -260 to + 1370 deg. C | 0.1 deg. C | 1 deg. C |
| T | -260 to + 390 deg. C | 0.1 deg. C | 1 deg. C |
| E | -260 to + 990 deg. C | 0.1 deg. C | 1 deg. C |
| R | -40 to + 1760 deg. C | 0.1 deg. C | 1 deg. C |
| S | -40 to + 1760 deg. C | 0.1 deg. C | 1 deg. C |
| B | 50 to + 1810 deg. C | 0.1 deg. C | 1 deg. C |
| N | -260 to +1290 deg. C | 0.1 deg. C | 1 deg. C |
|
Thermocouple connection: |
Screw Terminal |
|
Thermocouple Types: |
J, K, T, E, R, S, B, N |
|
Thermocouples: |
Factory supplied to customer specifications. |
|
Input Channels: |
2 - 1 internal and 1 external |
|
Input Impedance: |
>1Meg and 30pF |
|
Temperature Calibration: |
Digital Calibration available through software. Calibration correction value stored in device for internal channel as well as thermocouple. |
|
Cold Junction Compensation: |
Automatic |
|
N.I.S.T. Traceable: |
N.I.S.T. certificates available. |
|
Calibration Date: |
Automatically recorded in non-volatile memory within device. Reminds user when calibration is required. |
|
Transmission Interval: |
2 seconds, 5 seconds, 10 seconds, 15 seconds, 30 seconds, 1 minute, 5 minutes, 10 minutes, 15 minutes, 30 minutes, 1 hour, 2 hours, 4 hours, 8 hours, 24 hours. |
|
Start Time: |
The start time and date is completely programmable enabling users to synchronize multiple devices and delay start of data collection until device is in place. |
|
Real Time Recording: |
Device may be used to with pc to monitor and record data in real time. |
|
Red Visual Indicator: |
Red LED flashes at the reading interval to indicate device operational. |
|
User-Replaceable Battery: |
1 year typical. |
|
Time Accuracy: |
± 1 minute per month at 20 Deg C. |
|
Data Format: |
Date and Time stamped Deg C, Deg F, Deg K, Deg R. |
|
Shock resistance: |
Drop proof to 5’ |
|
Weight: |
1 oz (25.5g) |
|
Computer Interface: |
PC serial or RS232C COM |
|
Software: |
Windows 95-based software for complete control and operation. |
|
Operating Environment: |
-40 Deg C to 75 Deg C, 0 to 95% RH. (non-condensing) |
|
Dimensions: |
0.6" x 1.4" x 2.15" (15mm x 35mm x 54mm) |
|
Material: |
ABS Plastic |
Barnstead/ERTCO Thermometers |
|
![]() |
| manufactured by Barnstead International |
|